• DocumentCode
    3455949
  • Title

    Identification of unstable DC operating points

  • Author

    Biolek, Dalibor

  • Author_Institution
    Dept. of Electr. Eng., VA Brno, Brno, Czech Republic
  • Volume
    2
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    489
  • Abstract
    The Green´s “Γ-test” for identifying some unstable DC operating points of nonlinear resistive networks is analyzed. We show that some unstable operating points cannot be identified using this procedure. The described method is equivalent to the sign testing of a certain determinant of the DC circuit linearized around its operating point. Finally, we indicate a more general method based on the necessary condition of the DC operating point (in)stability
  • Keywords
    cascade networks; circuit analysis computing; circuit feedback; circuit stability; determinants; eigenvalues and eigenfunctions; matrix algebra; nonlinear network analysis; signal flow graphs; Green´s Γ-test; Mason´s graph; cascade circuits; circuit graphs; circuit matrices; determinant; gain product; identification; linearized circuit; multiple feedback circuits; nonlinear resistive networks; self-loops; sign testing; signal flow graph; unstable DC operating points; virtual eigenvalues; virtual voltages; Circuit stability; Circuit testing; Concrete; Differential equations; Flow graphs; Nonlinear circuits; Vectors; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics, Circuits and Systems, 1998 IEEE International Conference on
  • Conference_Location
    Lisboa
  • Print_ISBN
    0-7803-5008-1
  • Type

    conf

  • DOI
    10.1109/ICECS.1998.814927
  • Filename
    814927