DocumentCode :
3455949
Title :
Identification of unstable DC operating points
Author :
Biolek, Dalibor
Author_Institution :
Dept. of Electr. Eng., VA Brno, Brno, Czech Republic
Volume :
2
fYear :
1998
fDate :
1998
Firstpage :
489
Abstract :
The Green´s “Γ-test” for identifying some unstable DC operating points of nonlinear resistive networks is analyzed. We show that some unstable operating points cannot be identified using this procedure. The described method is equivalent to the sign testing of a certain determinant of the DC circuit linearized around its operating point. Finally, we indicate a more general method based on the necessary condition of the DC operating point (in)stability
Keywords :
cascade networks; circuit analysis computing; circuit feedback; circuit stability; determinants; eigenvalues and eigenfunctions; matrix algebra; nonlinear network analysis; signal flow graphs; Green´s Γ-test; Mason´s graph; cascade circuits; circuit graphs; circuit matrices; determinant; gain product; identification; linearized circuit; multiple feedback circuits; nonlinear resistive networks; self-loops; sign testing; signal flow graph; unstable DC operating points; virtual eigenvalues; virtual voltages; Circuit stability; Circuit testing; Concrete; Differential equations; Flow graphs; Nonlinear circuits; Vectors; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics, Circuits and Systems, 1998 IEEE International Conference on
Conference_Location :
Lisboa
Print_ISBN :
0-7803-5008-1
Type :
conf
DOI :
10.1109/ICECS.1998.814927
Filename :
814927
Link To Document :
بازگشت