DocumentCode
3457115
Title
Performance tests of the SLD barrel CRID detector components
Author
Antilogus, P. ; Aston, D. ; Bienz, T. ; Bird, F. ; Dasu, S. ; Dolinsky, Sergei ; Dunwoodie, W. ; Hallewell, G. ; Kawahara, H. ; Kwon, Youngwoo ; Leith, D. J. ; Muller, Dirk ; Nagamine, T. ; Pavel, T. ; Ratcliff, B. ; Rensing, P. ; Schultz, D. ; Shapiro, S
Author_Institution
SLAC, Stanford Univ., CA, USA
fYear
1991
fDate
2-9 Nov. 1991
Abstract
Summary form only given. The SLAC Large Detector (SLD) barrel Cerenkov ring imaging detector (CRID) is now complete and has participated in SLD data runs. Performance tests of the drift boxes and detectors both in the SLD and in separate test stands have been performed. Tests in SLD with the fiber-optic calibration system include the demonstration and measurement of electron drift paths, checks of the anode wire calibration, and the performance of the fiber-optic system in general. Other tests include measurements of the uniformity of TMAE concentration in a drift box and measurements of single electron diffusion and photon feedback in three drift gases.<>
Keywords
Cherenkov counters; calibration; position sensitive particle detectors; Cerenkov ring imaging detector; SLAC Large Detector; SLD barrel CRID detector; TMAE concentration; anode wire calibration; drift boxes; electron drift paths; fiber-optic calibration system; performance tests; photon feedback; single electron diffusion; Anodes; Calibration; Detectors; Electrons; Feedback; Optical fiber testing; Performance evaluation; Superluminescent diodes; System testing; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location
Santa Fe, NM, USA
Print_ISBN
0-7803-0513-2
Type
conf
DOI
10.1109/NSSMIC.1991.258941
Filename
258941
Link To Document