DocumentCode
3457450
Title
A combination drift chamber/pad chamber for very high readout rates
Author
Spiegel, L. ; Alexopoulos, T. ; Antoniazzi, L. ; Arenton, M. ; Ballagh, C. ; Bingham, H. ; Blankman, A. ; Block, M. ; Boden, A. ; Borodin, S. ; Budagov, J. ; Cao, Z.L. ; Cataldi, G. ; Chen, T.Y. ; Clark, K. ; Cline, D. ; Conetti, S. ; Cooper, M. ; Corti,
Author_Institution
Fermi Nat. Accelerator Lab., Batavia, IL, USA
fYear
1991
fDate
2-9 Nov. 1991
Firstpage
381
Abstract
Details of the construction of high-rate, mid-sized (1-m*2-m) pad chambers, intended for use in Fermi National Accelerator Laboratory (FNAL) experiment E-771, are described. Each gas volume module represents a chamber doublet: two identical anode wire planes, two transverse strip planes, and two pad planes. Wire signals, from 8-mm square cells, are recorded via TDCs; corresponding stripe and pad image signals are latched. Pad sizes range from 0.8 cm*3.6 cm to 3.2 cm*35 cm. In addition to facilitating pattern recognition, pad signals are also used as inputs to an online, high transverse momentum trigger processor.<>
Keywords
position sensitive particle detectors; proportional counters; 0.8 cm; 1 m; 2 m; 3.2 cm; 3.6 cm; 35 cm; anode wire planes; combination drift chamber/pad chamber; gas volume module; high transverse momentum trigger processor; pad planes; pattern recognition; transverse strip planes; very high readout rates; Anodes; Atherosclerosis; Coordinate measuring machines; Educational institutions; Laboratories; Mirrors; Pattern recognition; Programmable logic arrays; Signal processing; Wires;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location
Santa Fe, NM, USA
Print_ISBN
0-7803-0513-2
Type
conf
DOI
10.1109/NSSMIC.1991.258954
Filename
258954
Link To Document