DocumentCode
3458292
Title
A way for increasing the accuracy of an AC-PJVS
Author
Katkov, A. ; Behr, R. ; Palafox, L.
Author_Institution
Mendeleyev Inst. for Metrol., St. Petersburg, Russia
fYear
2010
fDate
13-18 June 2010
Firstpage
193
Lastpage
194
Abstract
This article proposes a way for increasing the accuracy of calculable AC voltages from an AC-Programmable Josephson Voltage Standard (AC-PJVS). Combining meander-like waveforms reduces difficulties concerning transients, source instabilities and non-sinusoidal waveforms. Thus uncertainties of an AC-PJVS can be reduced.
Keywords
measurement standards; voltage measurement; waveform analysis; AC voltage calculation; AC-PJVS accuracy; AC-Programmable Josephson Voltage Standard; meander-like waveforms; nonsinusoidal waveforms; source instabilities; Electromagnetic measurements; Frequency; Measurement standards; Metrology; Microwave antenna arrays; Pulse width modulation; Space vector pulse width modulation; Time measurement; Uncertainty; Voltage;