Title :
Droplet network connected by biological nanopores for DNA computing
Author :
Yasuga, H. ; Kawano, R. ; Takinoue, M. ; Tsuji, Yukihide ; Osaki, T. ; Kamiya, K. ; Miki, Nobuhiko ; Takeuchi, Shoji
Author_Institution :
Kanagawa Acad. of Sci. & Technol., Kawasaki, Japan
Abstract :
This paper experimentally describes formation of lipid-coated droplet network and demonstrates a biological NAND logic gate using this network and DNA. Droplets which compose this network are comparted by bilayer lipid membranes (BLMs) and connected via biological nanopores of membrane proteins, which ssDNA passes through. In the geometry of the droplet network, four droplets were placed at the corners and the center of an equilateral triangle. Inputs corresponded to the DNA translocation via biological nanopores from the two droplets at the corners (#1 and 2 in Fig. 1) to the center (#3 in Fig. 1), which can be controlled by the applied electrical fields between the droplets. Output was determined by whether DNA translocation occurred through nanopores between the center (#3 in Fig. 1) and the other corner droplet (#4 in Fig. 1). We believe that this system enables direct connection between electrical systems and computing with biomolecules.
Keywords :
DNA; biocomputing; bioelectric phenomena; biological techniques; biomembrane transport; drops; lipid bilayers; logic gates; nanoporous materials; proteins; DNA computing; DNA translocation; applied electrical fields; bilayer lipid membranes; biological NAND logic gate; biological nanopores; biomolecule computing; droplet network geometry; electrical systems; equilateral triangle; lipid-coated droplet network formation; membrane proteins; ssDNA; Biomembranes; DNA; Lipidomics; Logic gates; Nanobioscience; Proteins; α-Hemolysin; Bilayer Lipid Membrane; Biological Nanopore; DNA; Droplet Contact Method; Droplet Network; Streptolysin O;
Conference_Titel :
Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII), 2013 Transducers & Eurosensors XXVII: The 17th International Conference on
Conference_Location :
Barcelona
DOI :
10.1109/Transducers.2013.6626994