DocumentCode
3458427
Title
Array transducers based on 2-2 piezocomposites
Author
Lamberti, N. ; De Espinosa, F. Montero ; Iula, A. ; Pappalardo, M.
Author_Institution
Univ. di Salerno, Fisciano, Italy
Volume
2
fYear
1996
fDate
3-6 Nov 1996
Firstpage
963
Abstract
The trade-off between sensitivity and bandwidth in ultrasonic transducers devoted to NDT purposes is sometimes unbalanced in favour of sensitivity, due to the attenuation of the materials and structures to be inspected. Array transducers have been scarcely used in NDT due to standards´ constraints. To improve the bandwidth of the transducers without lowering the sensitivity, a piezoelectric composite multifrequency approach has been used. The single array element is composed of the parallel connection of piezoelectric bars with the same thickness but different width. A model which takes into account the propagation through both the thickness and width directions in isotropic and piezoelectric materials, has been used to optimize the geometry of single transducer element. The increase of the bandwidth can be as much as 50% with the same, at least, high sensitivity
Keywords
composite materials; inspection; piezoelectric materials; piezoelectric transducers; ultrasonic materials testing; ultrasonic transducer arrays; 2-2 piezocomposites; NDT; US transducers; array transducers; bandwidth; parallel connection; piezoelectric bars; piezoelectric composite multifrequency approach; sensitivity; Attenuation; Bandwidth; Bars; Inspection; Piezoelectric materials; Piezoelectric transducers; Polymers; Strips; Ultrasonic transducer arrays; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 1996. Proceedings., 1996 IEEE
Conference_Location
San Antonio, TX
ISSN
1051-0117
Print_ISBN
0-7803-3615-1
Type
conf
DOI
10.1109/ULTSYM.1996.584151
Filename
584151
Link To Document