DocumentCode
3458888
Title
Measurement of threshold level of FM signal demodulators
Author
Iskiv, W.M. ; Michayluck, Y.P.
Author_Institution
Sevastopol State Tech. Univ., Ukraine
fYear
1999
fDate
13-16 Sept. 1999
Firstpage
382
Lastpage
383
Abstract
The analysis of well known methods of measurement of threshold level of FM signal demodulators is represented. In view of the outcomes of the analysis the new method based on use of an immediate measurement of potency of threshold noise on an exit of the researched demodulator by a subtraction from an output signal of a modulating signal with known parameters, is offered.
Keywords
demodulators; electric noise measurement; noise generators; FM signal demodulators; modulating signal; output signal; subtraction; threshold level; threshold noise; Continuous wavelet transforms; Demodulation; Frequency modulation; Helium; IEEE catalog; Magnetic flux leakage; Noise measurement; Organizing; Signal analysis; Sprites (computer);
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 1999. Microwave & Telecommunication Technology. 1999 9th International Crimean [In Russian with English abstracts]
Conference_Location
Sevastopol, Crimea, Ukraine
Print_ISBN
966-572-003-1
Type
conf
DOI
10.1109/CRMICO.1999.815279
Filename
815279
Link To Document