• DocumentCode
    3458935
  • Title

    Inverter power drive transistor diagnostic and extended operation under one-transistor trigger suppression

  • Author

    Ginart, Antonio ; Brown, Douglas ; Kalgren, Patrick ; Roemer, Michael J.

  • Author_Institution
    Impact Technol., LLC, Atlanta, GA
  • fYear
    2008
  • fDate
    24-28 Feb. 2008
  • Firstpage
    873
  • Lastpage
    878
  • Abstract
    A fault-accommodation technique proposed for inverter drive systems extends the operation of an electrical power drive during an incipient power transistor fault. The discussed technique utilizes diagnostic methods to identify and isolate degraded power transistors. Once isolated, a suitable fault-accommodating control method using one-transistor trigger suppression (OTTS) control relieves electrical overstress applied to the degraded transistor to maintain operation of the motor while avoiding an inverter failure. Feasibility of the proposed method is demonstrated using V/f and vector techniques with an additional external fuzzy control for startup and steady-state conditions. Also discussed are advantages and potential drawbacks of this technique.
  • Keywords
    AC motor drives; fault diagnosis; fuzzy control; invertors; machine control; power transistors; degraded power transistors; electrical overstress; electrical power drive; external fuzzy control; fault-accommodating control method; fault-accommodation technique; inverter failure; inverter power drive; one-transistor trigger suppression; power transistor fault; Inverters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
  • Conference_Location
    Austin, TX
  • ISSN
    1048-2334
  • Print_ISBN
    978-1-4244-1873-2
  • Electronic_ISBN
    1048-2334
  • Type

    conf

  • DOI
    10.1109/APEC.2008.4522823
  • Filename
    4522823