• DocumentCode
    3459637
  • Title

    Performance Improvement of Ultrasonic Doppler Flowmeter Using Spread Spectrum Technique

  • Author

    Licun, Qiu ; Rulin, Wang

  • Author_Institution
    School of Mechanical Electronic & Information Engineering, China University of Mine & Technology (Beijing), Beijing 100083, the People´´s Republic of China, qiulicun@126.com
  • fYear
    2006
  • fDate
    Aug. 2006
  • Firstpage
    122
  • Lastpage
    126
  • Abstract
    A new method of ultrasonic flow rate measurement is presented. The range resolution of flow rate measurement is provided without velocity limitation and the same frequency interference also can be reduced greatly. In this method a pseudo random code is applied to modulate transmitting signal, the spectrum is spread widely. Receiving signal of interest region can be recovered by demodulation, because of the pseudo random code has characteristics of sharp autocorrelation. Thus the function of range resolution is realized. At the same time the same frequency interference spectrum is still spread widely, so the interference is reduced after passing a band-pass filter. The principle of the system is introduced in details. The realization of measuring system and the results of experiment are presented too.
  • Keywords
    Autocorrelation; Demodulation; Fluid flow measurement; Frequency measurement; Interference; Modulation coding; Signal resolution; Spread spectrum communication; Ultrasonic variables measurement; Velocity measurement; Doppler; Spread; Ultrasonic Doppler flowmeter; spectrum;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Acquisition, 2006 IEEE International Conference on
  • Conference_Location
    Veihai, China
  • Print_ISBN
    1-4244-0528-9
  • Electronic_ISBN
    1-4244-0529-7
  • Type

    conf

  • DOI
    10.1109/ICIA.2006.305935
  • Filename
    4097868