• DocumentCode
    3460295
  • Title

    Comparison of 3 absolute gravimeters based on different methods for the e-MASS project

  • Author

    Merlet, S. ; Agostino, G.D. ; Germak, A. ; Baumann, H. ; Bodart, Q. ; Louchet, A. ; Landragin, A. ; Santos, F. Pereira dos

  • Author_Institution
    LNE-SYRTE, UPMC, Paris, France
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    68
  • Lastpage
    69
  • Abstract
    The three INMs involved in the JRP e-MASS project operate three different absolute gravimeters, which rely on three different measurement methods. METAS operates a commercial FG5 gravimeter, INRIM has been developing his own ballistic symmetrical rise-and-fall gravimeter IMGC-2 and LNE-SYRTE develops a cold atom gravimeter. These gravimeters are briefly described in this paper and their differences and performances are discussed. The results of a comparison performed at the LNE laboratory will be presented.
  • Keywords
    gravimeters; FG5 gravimeter; JRP e-MASS project; atom gravimeter; ballistic symmetrical rise and fall gravimeter; measurement method; Acceleration; Atomic beams; Atomic measurements; Gravity measurement; Instruments; Interferometry; Laboratories; Laser transitions; Testing; Trajectory;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5543307
  • Filename
    5543307