DocumentCode
3460333
Title
Design and Performance of NSTX Movable GDC Probe
Author
Kugel, H.W. ; Maingi, R. ; Bell, Michael ; Blanchard, W. ; Gates, D. ; Gernhardt, R.
Author_Institution
Princeton Plasma Phys. Lab., Princeton
fYear
2007
fDate
17-21 June 2007
Firstpage
1
Lastpage
4
Abstract
The NSTX GDC system has been improved by replacing one of the two fixed anodes with a movable GDC probe (MGP) anode that can be inserted 1.2 m to about midway between the inner and outer vessel walls. The purpose was to provide more spatially uniform HeGDC for improving discharge stability and reliability. The MGP has been used reliably between every discharge during the last two NSTX experimental campaigns. It has also been used to apply HeGDC assisted boronization, and more recently, HeGDC assisted lithiumization. The MGP has contributed to improved NSTX performance during long pulse and H-mode discharges, and enabled a faster discharge repetition rate.
Keywords
Tokamak devices; anodes; glow discharges; plasma chemistry; plasma impurities; plasma probes; plasma-wall interactions; H-mode discharges; He glow discharge cleaning assisted boronization; He glow discharge cleaning assisted lithiumization; National Spherical Torus Experiment; anodes; discharge stability; impurity control; inner vessel wall; long pulse discharge; movable glow discharge cleaning probe; outer vessel wall; tokamaks; Anodes; Bellows; Breakdown voltage; Ceramics; Cleaning; Glow discharges; Ground support; Laboratories; Plasmas; Probes; component; glow discharge cleaning; impurity control; tokamaks; wall conditioning;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 2007. SOFE 2007. 2007 IEEE 22nd Symposium on
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-1193-1
Electronic_ISBN
978-1-4244-1194-8
Type
conf
DOI
10.1109/FUSION.2007.4337871
Filename
4337871
Link To Document