  • Abstract
    The goal of this paper is to propose a fault tolerant system for a single-phase to three-phase ac drive system. Open circuit and short circuit failures are considered in this work as non-programmed maintenance troubles occurring in the converter power devices, and it can be compensated by proposed strategy. The fault compensation is achieved by reconfiguring the power converter topology with the help of isolation and connection devices. These devices are used to redefine the post-fault ac drive system topology. The post-fault converter topology associated to the control strategy allows to keep the ac drive system operating with dc-link voltage equal or close to that of the pre-fault system. Experimental results demonstrate the validity of the proposed system.
  • Keywords
    AC motor drives; fault diagnosis; maintenance engineering; power convertors; short-circuit currents; ac drive fault tolerant system; converter power devices; nonprogrammed maintenance troubles; open circuit; post-fault converter topology; power converter topology; short circuit failures; single-phase grid; three-phase ac drive system; Capacitors; Circuit faults; Fault tolerant systems; Jacobian matrices; Leg; Switches; Switching converters; Thyristors; Topology; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE
  • Conference_Location
    Austin, TX
  • ISSN
    1048-2334
  • Print_ISBN
    978-1-4244-1873-2
  • Electronic_ISBN
    1048-2334
  • Type

    conf

  • DOI
    10.1109/APEC.2008.4522977
  • Filename
    4522977