Title :
A rotating PET camera using BGO block detectors
Author :
Townsend, D. ; Wensveen, M. ; Byars, L. ; Geissbuhler, A. ; Tochon-Danguy, Henri ; Christin, Anne ; Defrise, Michel ; Kuijk, Sytse ; GrootoonK, Sylke ; Nutt, Ronald
Author_Institution :
Div. of Nucl. Med., Geneva Univ. Hospital, Switzerland
fYear :
1991
fDate :
2-9 Nov. 1991
Firstpage :
1658
Abstract :
A positron emission tomography (PET) scanner with a reduced number of detectors per ring subtending two opposing arcs of 60 degrees and mounted on a circular support was developed. Projection data at all angles are acquired by rotating the detector assembly. The scanner has no septa, and data from the equivalent of 16 full rings of detectors are collected and sorted into 256 sinograms. The number of rotational positions at which data must be acquired depends on the size of the field of view (FOV) required. Reconstruction is performed using a fully 3-D reconstruction algorithm. The scanner has an absolute efficiency of 0.5% at the center of the FOV, which is the same as that of a full ring scanner with septa extended. The sensitivity measured with a 20-cm uniform cylinder is 175000 cps/ mu Ci/ml, and the transaxial and axial spatial resolution is the same as for a full ring scanner ( approximately 6 mm). The scatter fraction is 39% with a lower energy threshold at 250 keV. The maximum noise equivalent count rate estimated for a 15-cm-diameter cylinder is 42000 cps at a concentration of 0.5 mu Ci/ml. The camera was used for a number of /sup 18/FDG applications in neurology, cardiology, and oncology.<>
Keywords :
biomedical equipment; cameras; computerised tomography; radioisotope scanning and imaging; 15 cm; 20 cm; 250 keV; 3D reconstruction algorithm; BGO block detectors; axial spatial resolution; cardiology; circular support; detector assembly rotation; energy threshold; field of view size; full ring scanner; medical diagnostic imaging; medical instrumentation; neurology; nuclear medicine; oncology; projection data; rotating PET camera; rotational positions; scatter fraction; sinograms; Assembly; Cameras; Cardiology; Detectors; Nervous system; Oncology; Positron emission tomography; Scattering; Spatial resolution; Three dimensional displays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Santa Fe, NM, USA
Print_ISBN :
0-7803-0513-2
Type :
conf
DOI :
10.1109/NSSMIC.1991.259196
Filename :
259196
Link To Document :
بازگشت