• DocumentCode
    3461886
  • Title

    Comparison of NIM and BIRMM Programmable Josephson Voltage Standards

  • Author

    Gao, Yuan ; Li, Honghui ; Wang, Zengmin ; Kang, Yan ; Wang, Lu ; Zhang, Hui ; Zhu, Zhu

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    52
  • Lastpage
    53
  • Abstract
    A comparison between the National Institute of Metrology (NIM) and the Beijing Institute of Radio Metrology and Measurement (BIRMM) Programmable Josephson Voltage Standards (PJVS) at 1 V level was carried out at Changping campus of NIM from November 16 to November 17, 2009. The measured difference voltage between the two PJVS is 2×10-10 in direct comparison and 4×10-9 in indirect comparison. The results of this comparison have demonstrated excellent agreement between the NIM and the BIRMM PJVSs.
  • Keywords
    measurement standards; voltage measurement; BIRMM; Beijing Institute of Radio Metrology and Measurement; Changping campus; NIM; National Institute of Metrology; PJVS; programmable Josephson voltage standards; voltage 1 V; Data acquisition; Detectors; Electromagnetic measurements; Insulation; Josephson junctions; Measurement standards; Metrology; Millimeter wave measurements; Superconducting microwave devices; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5543407
  • Filename
    5543407