Title :
New reference measurement system for calibration of VLF high voltage
Author :
Bergman, S. ; Bergman, A.
Author_Institution :
SP Tech. Res. Inst. of Sweden, Boras, Sweden
Abstract :
A reference measuring system for 200 kV at very low frequency (0.1 Hz, VLF) has been developed and verified. The reference system will make it possible to perform traceable calibration of VLF test systems used for after-laying-tests of extruded power cables.
Keywords :
calibration; measurement systems; power cables; VLF high voltage; calibration; extruded power cables; reference measurement system; Cable insulation; Calibration; Capacitance measurement; Capacitors; Electromagnetic measurements; Frequency conversion; Low voltage; Power cables; System testing; Voltage measurement;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
DOI :
10.1109/CPEM.2010.5543426