• DocumentCode
    3462240
  • Title

    A method to correct inductive voltage dividers error caused by capacitances between winding and screen

  • Author

    Jianting, Zhao ; Qing, He ; Yunfeng, Lu

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    394
  • Lastpage
    395
  • Abstract
    Distributed shunt impedances and leakage impedances in the windings of inductive voltage dividers (IVDs) cause the major components of ac voltage ratio errors, and these two kinds of errors had been well investigated from both theory and experiments. The winding -to-screen capacitances of IVDs can also introduce small but significant ratio error. A theoretical analysis result for this kind of error has been obtained, and a method to correct this kind of error has been presented.
  • Keywords
    voltage dividers; ac voltage ratio errors; distributed shunt impedances; inductive voltage dividers error; leakage impedances; winding-to-screen capacitances; Capacitance; Capacitors; Electromagnetic measurements; Error correction; Impedance; Magnetic separation; Magnetic shielding; Toroidal magnetic fields; Voltage; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5543427
  • Filename
    5543427