• DocumentCode
    3462600
  • Title

    A prototype emission-transmission imaging system

  • Author

    Lang, T.F. ; Hasegawa, B.H. ; Liew, S.C. ; Brown, J.K. ; Blankespoor, S. ; Reilly, S.M. ; Gingold, E.L. ; Cann, C.E.

  • Author_Institution
    California Univ., San Francisco, CA, USA
  • fYear
    1991
  • fDate
    2-9 Nov. 1991
  • Firstpage
    1902
  • Abstract
    The prototype imaging system developed can perform simultaneous X-ray transmission CT (computed tomography) and SPECT (single photon emission computed tomography) studies of phantoms and small animals. This system uses a small linear detector array which consists of a single high-purity-germanium crystal segmented by ion-implantation into 23 2-mm elements. The detector array and its associated electronics can sustain count rates up to 10/sup 6/ cps/element while maintaining sufficient energy resolution to discriminate between X-rays at tube potentials of 100-120 kV and higher-energy gamma -rays from /sup 99m/Tc and /sup 123/I. The data acquisition system supports two energy windows per channel and may be used for emission-transmission or dual-energy X-ray imaging. Initial studies have demonstrated that X-ray CT and SPECT images acquired with this device are spatially correlated and may be superimposed to localize the SPECT image on the transmission map. Preliminary data also show that it is possible to use dual-energy X-ray CT to derive an object-specific attenuation map at the radionuclide energy. This attenuation map may then be incorporated into an iterative reconstruction algorithm to yield significant improvements in SPECT quantitation.<>
  • Keywords
    biomedical equipment; computerised tomography; radioisotope scanning and imaging; /sup 123/I; /sup 99m/Tc; 100 to 120 kV; 2 mm; SPECT; X-ray transmission CT; data acquisition system; energy resolution; energy windows; ion implantation; iterative reconstruction algorithm; object-specific attenuation map; phantoms; prototype emission-transmission imaging system; radionuclide energy; single photon emission computed tomography; small animals; small linear detector array; tube potential; Animals; Attenuation; Computed tomography; Detectors; Imaging phantoms; Optical imaging; Prototypes; Sensor arrays; Single photon emission computed tomography; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
  • Conference_Location
    Santa Fe, NM, USA
  • Print_ISBN
    0-7803-0513-2
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1991.259246
  • Filename
    259246