DocumentCode :
3466089
Title :
Scaling of inductance to the pH-level
Author :
Rydler, K.-E. ; Tarasso, V. ; Bergsten, T.
Author_Institution :
SP Tech. Res. Inst. of Sweden, Boras, Sweden
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
384
Lastpage :
385
Abstract :
The paper presents a method to calibrate four-terminal pair inductance meters at the pH-level and frequencies up to 1 MHz using calculable inductance standards in the nH-range and scaling by a wideband resistive voltage divider.
Keywords :
inductance measurement; pH measurement; inductance meter; inductance scaling; inductance standard; pH level; wideband resistive voltage divider; Displacement measurement; Electrical resistance measurement; Impedance measurement; Inductance measurement; Inductors; Measurement standards; Phase measurement; Shunt (electrical); Voltage; Wideband;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5543665
Filename :
5543665
Link To Document :