• DocumentCode
    3467793
  • Title

    Analysis and design of Makowski charge-pump cell

  • Author

    Liu, Lifang ; Chen, Zhiliang

  • Author_Institution
    Inst. of Microelectron., Tsinghua Univ., Beijing
  • Volume
    1
  • fYear
    2005
  • fDate
    24-0 Oct. 2005
  • Firstpage
    497
  • Lastpage
    502
  • Abstract
    In designing a charge pump cell, selection of switching frequency and component sizes is usually a problem. There have been some discussions about Dickson charge pump and most of them considered the frequency and component sizes respectively. In this paper, a new and generalized method for the analysis and design of Makowski charge pump is presented. Switching frequency and component sizes are considered as a whole. Voltage loss and power loss are presented in detail. Conduction and switching losses are evaluated to achieve design optimization in terms of switching frequency and component sizes. Practical designs and simulations are performed to prove the validity and accuracy of the theoretical analysis and optimization. It shows that the switching frequency and the component sizes obtained from the analysis give us near-optimal power efficiency. A 6 or 8 times Makowski charge pump cell is also designed based on our theory
  • Keywords
    DC-DC power convertors; Dickson charge pump; Makowski charge-pump cell; conduction losses; power loss; switching frequency; switching losses; voltage loss; Capacitors; Charge pumps; DC-DC power converters; Design methodology; Design optimization; Microelectronics; Steady-state; Switches; Switching frequency; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ASIC, 2005. ASICON 2005. 6th International Conference On
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-9210-8
  • Type

    conf

  • DOI
    10.1109/ICASIC.2005.1611328
  • Filename
    1611328