• DocumentCode
    3467895
  • Title

    Wide area measurement & control system in Mexico

  • Author

    Martínez, Enrique Martínez

  • Author_Institution
    Fed. de Electr. (CFE), Mexico City
  • fYear
    2008
  • fDate
    6-9 April 2008
  • Firstpage
    156
  • Lastpage
    161
  • Abstract
    The wide-area synchronized phasor measurement system envisioned by Comision Federal de Electricidad (CFE) during the 1990´s and designed to increase the security and integrity of Mexico´s electric power system. This paper presents the different development stages taken for the deployment of WAMS. Details of the current state and PMU data-based application examples within CFE are also provided. CFE has a potential of more than 140 Units of Mensuration Fasorial (PMU´s) and relays protection with phasor measurement functions of different manufactures and models, installed in the three different electric power systems. The project of a Wide Area Measurement System of CFE is conformed by regional data concentrators of PMU´s, located in each Regional Management of Transmission or Control Areas, and a Central Unit or super concentrator. In this Centrl Unit is possible to save the files for analysis post mortem. Also is possible the visualization in real time of voltage, frequency, fase angle, MW and MVAR in different points of the electric systems. During ten years of experience with sincrofasors, the CFE has developed applications for the analysis of fauls and reproduction of events. Also, with the registrations of PMU´s regulators, stabilizers and underfrequency load shedding schems have been adjusted. At the moment, in CFE are working in the development of applications for the Automatic Generation Shedding Schemes (AGSSs) using Phasor Measurement and Control Units PMCU´s.
  • Keywords
    load shedding; phase measurement; power system control; power system faults; power system measurement; power system protection; power system security; relay protection; Comision Federal de Electricidad; Mexico; PMU; automatic generation shedding schemes; regional data concentrators; regional management of transmission; relays protection; super concentrator; synchronized phasor measurement system; underfrequency load shedding schems; wide area measurement & control system; Control systems; Data security; Electric variables measurement; Frequency synchronization; Phasor measurement units; Power measurement; Power system security; Protective relaying; Virtual manufacturing; Wide area measurements; Phasor Measurement Unit (PMU); Real-Time Power System State Visualization; Wide Area Measurement Systems (WAMS);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Utility Deregulation and Restructuring and Power Technologies, 2008. DRPT 2008. Third International Conference on
  • Conference_Location
    Nanjuing
  • Print_ISBN
    978-7-900714-13-8
  • Electronic_ISBN
    978-7-900714-13-8
  • Type

    conf

  • DOI
    10.1109/DRPT.2008.4523394
  • Filename
    4523394