DocumentCode :
3468098
Title :
Preliminary results obtained from a novel CdZnTe pad detector and readout ASIC developed for an automatic baggage inspection system
Author :
Tümer, T.O. ; Clajus, M. ; Visser, G.I. ; Yin, S. ; Willson, P.D. ; D´Aries, L. ; Parnham, K.B. ; Glick, B. ; Perry, J.L. ; Gamble, T. ; Creede, G. ; Worthington, E. ; Sparling, J. ; Maeding, D. ; Gorzen, D.
Author_Institution :
NOVA R&D Inc., Riverside, CA, USA
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
13241
Abstract :
A linear CdZnTe pad detector array with approximately 1 mm2 pad area has been developed. The detector has a wide energy range from about 20 to 200 keV. A fast, low-noise monolithic mixed signal ASIC chip has been developed to read out these detector arrays. A prototype X-ray imaging system consisting of the CdZnTe detector array and the monolithic ASIC chip has been fabricated and tested. In this system, the detectors are abutted against each other to form an approximately 1 m long linear array. The system has been used to take preliminary scanned images of complex objects at various energies. New results obtained from this system is discussed
Keywords :
X-ray detection; X-ray imaging; digital readout; inspection; mixed analogue-digital integrated circuits; nuclear electronics; nuclear materials safeguards; readout electronics; semiconductor counters; 1 m; 1 mm; 20 to 200 keV; CdZnTe; automatic baggage inspection; fast low-noise monolithic mixed signal ASIC chip; linear array; nuclear safeguards; pad detector; prototype X-ray imaging; readout ASIC; Application specific integrated circuits; Atherosclerosis; Counting circuits; Energy resolution; Inspection; Prototypes; Sensor arrays; X-ray detection; X-ray detectors; X-ray imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2000 IEEE
Conference_Location :
Lyon
ISSN :
1082-3654
Print_ISBN :
0-7803-6503-8
Type :
conf
DOI :
10.1109/NSSMIC.2000.949044
Filename :
949044
Link To Document :
بازگشت