Abstract :
We have developed a new efficient optimization algorithm that uses the single equivalent moving dipole (SEMD) model to identify the electrical sources in the heart from body surface electrocardiographic (ECG) signals. In this paper we explored the ability of this algorithm to resolve the relative distance between epicardial pacing sites in an experimental animal model
Keywords :
covariance analysis; electrocardiography; medical signal processing; optimisation; physiological models; signal resolution; animal model; coefficient of variation; efficient optimization algorithm; epicardial pacing sites resolvability; equivalent cardiac dipole identification; fast method; single equivalent moving dipole model; surface ECG; Animals; Catheters; Electrocardiography; Heart; Measurement standards; Parameter estimation; Signal processing; Signal resolution; Surface fitting; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
ISSN :
1094-687X
Print_ISBN :
0-7803-5674-8
Type :
conf
DOI :
10.1109/IEMBS.1999.802381
Filename :
802381
Link To Document :
بازگشت