DocumentCode :
3469924
Title :
Calibration of magnetic field probes at relevant magnitudes
Author :
Pahl, Ryan A. ; Rovey, Joshua L. ; Pommerenke, David J.
Author_Institution :
Missouri Univ. of Sci. & Technol., Rolla, MO, USA
fYear :
2013
fDate :
16-21 June 2013
Firstpage :
1
Lastpage :
6
Abstract :
Difficulty driving large currents through an inductive load at high frequency typically results in field magnitudes of a few microTesla or less. The calibration factor is then necessarily assumed linear, even though the magnetic field of the primary experiment is several orders of magnitude larger than the field magnitude used to calibrate the probe. In this work calibration factors of two differential configuration magnetic field probes are presented as functions of frequency and field magnitude. Calibration factors are determined experimentally using a 80.4 mm radius Helmholtz coil in two separate configurations. A conventional low-magnitude calibration using a network analyzer with field magnitude of 158 nT yielded calibration factors of 15,107±233 and 4,899±180 T/V-s at 457 kHz for the surface mounted inductor and hand-wound probe, respectively. A relevant-magnitude calibration using a pulsed-power setup with field magnitude of 43.5 to 83.0 mT yielded calibration factors of 14,541±41.8 and 4,484±15.8 T/V-s at 457 kHz for the surface mounted inductor and hand-wound probe, respectively. The uncertainty reported is one standard deviation of the repeated calibration measurement. Low-magnitude calibration always resulted in a larger calibration factor, with a maximum difference of 18.5%. Comparison of the pulsed-power Helmholtz coil current waveform with the magnetic field waveform measured with the magnetic probes showed differences of 1.4% and 0.7% in the waveform extrema at 457 kHz for the surface mounted inductor and hand-wound probe, respectively.
Keywords :
calibration; coils; inductors; magnetic field measurement; magnetic sensors; probes; calibration factor; current waveform; hand wound probe; inductive load; low magnitude calibration; magnetic field probe calibration; magnetic field waveform; magnetic flux density 158 nT; magnetic flux density 43.5 mT to 83.0 mT; magnetic probe; network analyzer; pulsed power Helmholtz coil; size 80.4 mm; surface mounted inductor; Calibration; Coils; Inductors; Magnetic field measurement; Magnetic fields; Probes; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference (PPC), 2013 19th IEEE
Conference_Location :
San Francisco, CA
ISSN :
2158-4915
Type :
conf
DOI :
10.1109/PPC.2013.6627649
Filename :
6627649
Link To Document :
بازگشت