• DocumentCode
    3470033
  • Title

    Quasi-blind voltage contrast in e beam inspection

  • Author

    Hsiang-Chou Liao ; Hsiao-Leng Li ; Tuung Luoh ; Ling-Wu Yang ; Tahone Yang ; Kuang-Chao Chen ; Chih-Yuan Lu

  • Author_Institution
    Technol. Dev. Center, Macronix Int. Co. Ltd., Hsinchu, Taiwan
  • fYear
    2013
  • fDate
    6-6 Sept. 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The different inspection methodologies in e beam are put together to compare their inspection performance on irregularly periphery via plugs. The results demonstrate hot spot inspection mode has better alignment performance and higher sensitivity than leap and scan mode. Hot spot mode can inspect the tiny variation of voltage contrast (VC) with high sensitivities. One type of VC variation inspected by hot spot mode so call qausi-blind VC is addressed here that was not reported before.
  • Keywords
    electric connectors; electron beam applications; flash memories; inspection; vias; Flash product; VC variation inspection; alignment performance; e beam inspection; hot spot inspection mode; inspection methodology; inspection performance; leap-scan mode; periphery via plugs; qausiblind VC; quasiblind voltage contrast; sensitivity; Facsimile; Image resolution; Optical imaging; Optical sensors; Signal resolution; Stimulated emission; Hot Spot; Leap and Scan; Surface Charging; Voltage Contrast; e Beam Inspection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    e-Manufacturing & Design Collaboration Symposium (eMDC), 2013
  • Conference_Location
    Hsinchu
  • Type

    conf

  • DOI
    10.1109/eMDC.2013.6756063
  • Filename
    6756063