• DocumentCode
    3470593
  • Title

    MR-compatible shields for 511 keV gamma photons: a feasibility study

  • Author

    Strul, D. ; Cash, D. ; Keevil, S.F. ; Halstead, P. ; Williams, S.C.R. ; Marsden, P.K.

  • Author_Institution
    Guy´´s, King´´s & St. Thomas´´ Sch. of Med., King´´s Coll., London, UK
  • Volume
    3
  • fYear
    2000
  • fDate
    2000
  • Abstract
    An MR-compatible PET scanner capable of acquiring PET and MR images simultaneously will require 511 keV gamma shielding to suppress the influence of activity outside the PET field of view. Suitable materials must have a magnetic permeability close to that of water and air, high density, high Z and ideally a low conductivity. Eleven materials were selected on the basis of the criteria above, including various MRI magnetically-compatible metals and metal oxides, 2 scintillating crystals (bismuth germanate and lead tungstate), and 3 metal/epoxy compounds. Samples of these materials, immersed in a water-filed phantom, were first imaged on a human MRI-scanner to assess their MR-compatibility. A similar protocol was then applied to 3 annular shields, respectively made of red lead oxide, lead powder and bulk lead. Lastly, a water-filled phantom was imaged on a small-animal MRI scanner with the coil within annular shields made of bismuth germanate, sintered lead monoxide or bulk lead. These experiments showed that lead cannot be generally used for MR-compatible gamma shielding, since it yields conductivity-related artefacts or signal loss. The most promising candidates are high-density insulating compounds such as lead oxides, and crystalline scintillator materials such as bismuth germanate
  • Keywords
    biomedical MRI; biomedical equipment; positron emission tomography; shielding; 511 keV; 511 keV gamma photons; MR-compatible PET scanner; MR-compatible shields; Pb; annular shields; bulk lead; crystalline scintillator materials; dual-modality imaging; human MRI-scanner; lead powder; medical diagnostic imaging; medical instrumentation; metal/epoxy compounds; red lead oxide; scintillating crystals; small-animal MRI scanner; water-filled phantom; Bismuth; Conducting materials; Conductivity; Crystalline materials; Imaging phantoms; Lead compounds; Magnetic materials; Magnetic resonance imaging; Permeability; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949163
  • Filename
    949163