Title :
On the uncertainties of measurements international 8001A extender
Author :
Síra, M. ; Streit, J. ; Honig, R. ; Zachovalova, V. Novakova
Author_Institution :
Czech Metrol. Inst., Brno, Czech Republic
Abstract :
Automatic divider MI8000A is used to calibrate high precisions voltmeters up to ten volts. One have to use extender MI8001A to measure up to one thousand volts. As with software for the 8000A divider, calculation of uncertainties for this extender was corrected.
Keywords :
calibration; measurement uncertainty; voltage measurement; voltmeters; International 8001A Extender; automatic divider MI8000A; measurement uncertainties; voltage measurement; voltmeters calibration; Calibration; Detectors; Electromagnetic measurements; Measurement uncertainty; Relays; Resistors; Software measurement; Switches; Voltage; Voltmeters;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
DOI :
10.1109/CPEM.2010.5543953