DocumentCode :
3472389
Title :
Bridging RF-voltage to coaxial power standard in the 100 MHz range
Author :
Brunetti, L. ; Bussa, M.P. ; Oberto, L. ; Sellone, M.
Author_Institution :
Ist. Naz. di Ricerca Metrol. (INRIM), Torino, Italy
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
740
Lastpage :
741
Abstract :
Electromagnetic power standard realized by means of the microcalorimetric technique fails below some MHz because of a reduced sensitivity of the system. This causes a metrological lack in the calibration of coaxial power sensors whose broadband characteristics span from dc up to 50 GHz. However, as coaxial transmission lines admit pseudo potential functions, power meter calibration can be done in term of radio frequency (RF) voltage from dc up to 100 MHz at least. The paper describes how INRIM works around the drawback of the microcalorimeter at low frequencies.
Keywords :
calorimeters; coaxial cables; electric sensing devices; power meters; transmission lines; bridging RF-voltage; broadband characteristics span; coaxial power sensors; coaxial transmission lines; electromagnetic power standard; frequency 100 MHz; microcalorimetric technique; power meter calibration; pseudopotential functions; radiofrequency voltage; Analog-digital conversion; Coaxial components; Detectors; Frequency measurement; Measurement standards; Radio frequency; Sensor phenomena and characterization; Sensor systems; Thermoelectricity; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5544022
Filename :
5544022
Link To Document :
بازگشت