The influence of mechanical strain magnitude on bone adaptation to porous-coated implants
Author :
Borodkin, J. ; Caldwell, N. ; Hollister, S.
Author_Institution :
Dept. of Biomed. Eng., Michigan Univ., Ann Arbor, MI, USA
Abstract :
In order to investigate the hypothesis that trabecular bone tissue adapts its structure according to its mechanical strain magnitude, voxel-based FEA was used to model the interface mechanics of a hydraulically-loaded implant experiment. Although the applied loads produced a wide range of tissue strain levels, the loads were insufficient for preventing the long-term bone atrophy observed in unloaded bones. These results suggest that bone remodeling processes are influenced by other factors besides strain magnitude
Keywords :
biomechanics; biomedical materials; finite element analysis; orthopaedics; porous materials; prosthetics; applied loads; bone adaptation; bone remodeling processes; hydraulically-loaded implant experiment; insufficient loads; interface biomechanics; mechanical strain magnitude influence; porous-coated implants; strain magnitude; tissue engineering; tissue strain levels; voxel-based FEA; Atrophy; Biomedical engineering; Bone tissue; Cancellous bone; Capacitive sensors; Electronic mail; Implants; Laboratories; Orthopedic surgery; Tensile strain;
Conference_Titel :
[Engineering in Medicine and Biology, 1999. 21st Annual Conference and the 1999 Annual Fall Meetring of the Biomedical Engineering Society] BMES/EMBS Conference, 1999. Proceedings of the First Joint
Conference_Location :
Atlanta, GA
Print_ISBN :
0-7803-5674-8
DOI :
10.1109/IEMBS.1999.803923