Title :
Precision of the inverse matrix technique for space charge measurement with the thermal step method
Author :
Dakka, M. Abou ; Bamji, S.S. ; Bulinski, A.T.
Author_Institution :
Nat. Res. Council of Canada, Ottawa, Ont., Canada
Abstract :
The thermal step method (TSM) is a nondestructive technique for measuring space charge distribution in thick and thin insulating materials. Although the measurements are relatively simple and the required apparatus is inexpensive, the numerical analysis to deconvolute TSM currents into the space charge and electric field distributions is complex and time consuming. This paper describes the precision of a newly developed deconvolution technique based on the inverse matrix calculations. The effects of the specimen thickness, matrix size, number of iterations and the polymer-electrode interface on the error of the calculations are discussed
Keywords :
Fredholm integral equations; charge measurement; deconvolution; insulating materials; insulation testing; iterative methods; matrix inversion; space charge; Fredholm equation; calculation error; deconvolution technique; electric field distributions; inverse matrix technique; matrix size; nondestructive technique; number of iterations; polymer-electrode interface; precision; space charge measurement; specimen thickness; thermal step method; thick insulating materials; thin insulating materials; Charge measurement; Current measurement; Deconvolution; Electric variables measurement; Insulation; Numerical analysis; Polymers; Space charge; Thickness measurement; Time measurement;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1999 Annual Report Conference on
Conference_Location :
Austin, TX
Print_ISBN :
0-7803-5414-1
DOI :
10.1109/CEIDP.1999.804617