DocumentCode :
3474837
Title :
Estimation for degradation characteristics of cellulose paper used in oil-filled transformer and analysis for correlationship using statistical treatment
Author :
Kim, Jae Hoon ; Park, Doo Ki ; Han, Sang Ok
Author_Institution :
Chungnam Nat. Univ., Daejeon, South Korea
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
692
Lastpage :
693
Abstract :
This paper is aimed at evaluation about aging properties of cellulose paper used for insulating of oil-filled transformer and analysis on correlation between mechanical characteristic such as tensile strength and chemical characteristics such as CO, CO2 gas and furfural when cellulose paper is aged by thermal. For experiment the accelerated aging cell has been manufactured, it has been aged during 60 hours at 100, 150, 180 and 200[°C], respectively. It has been used DGA(dissolved gas analysis) and HPLC(high performance liquid chromatography) for degradation diagnosis. Also it has been established correlation between them using multiple regression analysis.
Keywords :
ageing; chromatography; paper; regression analysis; transformer oil; DGA; HPLC; aging properties evaluation; cellulose paper; chemical characteristics; dissolved gas analysis; high performance liquid chromatography; mechanical characteristic; oil-filled transformer insulation; regression analysis; statistical treatment; Accelerated aging; Chemical analysis; Gas insulation; Manufacturing; Mechanical factors; Oil insulation; Performance analysis; Power transformer insulation; Regression analysis; Thermal degradation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5544170
Filename :
5544170
Link To Document :
بازگشت