Abstract :
DC losses in the four-wire leads or connector of a microwave power transfer standard can result in incorrect effective efficiency measurements as measured by a calorimeter. Symptoms of the error and a method for setting an upper limit of its magnitude are described.
Keywords :
calorimeters; electric connectors; error analysis; losses; microwave detectors; DC losses; calorimetric effective efficiency measurements error; four wire lead; microwave power transfer standard; Connectors; Electrical resistance measurement; Electromagnetic heating; Electromagnetic measurements; Frequency measurement; Loss measurement; Microwave measurements; Power measurement; Radio frequency; Thermistors;