• DocumentCode
    3475164
  • Title

    Automatic extraction of stomach contour from barium filled X-ray image

  • Author

    Kobayashi, Fujio ; Ozaki, Makoto ; Tsutsumoto, Kazuhiro

  • Author_Institution
    Fukuayama Univ., Hiroshima, Japan
  • Volume
    3
  • fYear
    2000
  • fDate
    2000
  • Abstract
    A method of stomach extraction is proposed. The stomach contour is automatically and accurately extracted by the characteristics of the X-ray stomach image. First, the approximate region of stomach is obtained by the combination image which is constructed from binary of the original image and its differential image. Secondly, the stomach contour is extracted by the brightness of the differential image and the shape which is the approximate region of stomach. Thus, the stomach contour is accurately extracted. Lastly, this method was applied for many samples of X-ray images, and was proved to be effective
  • Keywords
    barium; biological organs; diagnostic radiography; feature extraction; medical image processing; Ba; automatic extraction; barium filled X-ray image; differential image; medical diagnostic imaging; stomach contour; Barium; Biomedical imaging; Brightness; Diseases; Equations; Flowcharts; Medical diagnostic imaging; Shape; Stomach; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.949395
  • Filename
    949395