Stringing haulage motors were main underground conveyance equipments, but they were the strong electromagnetic interference sources. To resolve the problem of monitor system false alarm and mobile communication interruption, the interference generation mechanism and distribution characteristic were analyzed. The means of conducted interference circuit analysis and stray current quantitative analysis were adopted. The radiated interference of the stringing haulage motor was measured with Protek3201 field-intensity meter at the second mine of Pingdingshan coal Co. Ltd. The conducted interference, stray current and radiated interference were the main factors of gas monitor and mobile communication malfunction. The anti-interference measures were taken, which included the power supply isolation, equipotential earth and shield to radiated interference. Results indicate monitor system false alarm and mobile communication interruption have been eliminated completely. It is concluded that the electromagnetic compatibility of underground gas monitor and mobile communication has been enhanced evidently with these anti- interference measures.
Keywords :
condition monitoring; electric motors; electromagnetic compatibility; electromagnetic interference; mining; mining equipment; mobile communication; underground equipment; Pingdingshan coal Co. Ltd; Protek3201 field-intensity meter; colliery mobile communication; electromagnetic compatibility; electromagnetic interference; gas monitor; interference circuit analysis; mobile communication interruption; monitor system false alarm; power supply isolation; radiated interference; stray current quantitative analysis; underground conveyance equipments; underground haulage motors; Character generation; Circuit analysis; Electromagnetic interference; Electromagnetic measurements; Electromagnetic radiative interference; Immunity testing; Mobile communication; Monitoring; Power measurement; Power supplies; coal mine mobile communication; electromagnetic compatibility; electromagnetic interference; gas monitor; stringing haulage motor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Automation and Logistics, 2007 IEEE International Conference on
Conference_Location :
Jinan
Print_ISBN :
978-1-4244-1531-1
Type :
conf
DOI :
10.1109/ICAL.2007.4339032
Filename :
4339032
Link To Document :
بازگشت