• DocumentCode
    3478285
  • Title

    Camera Calibration Method in Reverse Engineering

  • Author

    Lv, Qiujuan ; Hou, Genliang ; Luo, Zimig

  • Author_Institution
    Xi´´an Jiaotong Univ., Xi´´an
  • fYear
    2007
  • fDate
    18-21 Aug. 2007
  • Firstpage
    2936
  • Lastpage
    2939
  • Abstract
    Based on the two-dimensional method, camera calibration method was proposed in reverse engineering. First, obtain the initial value through the linear method; second, considering the radical and tangential distortion, optimize the results using maximum likelihood estimation method through the nonlinear method; at last, minimize the error by modifying the actual image point repeatedly. The experimental errors are 0.30267 pixels and 0.24683 pixels, respectively. This demonstrates that the method has a higher accuracy and is an effective and simple calibration method.
  • Keywords
    calibration; cameras; reverse engineering; Camera Calibration Method; Reverse Engineering; image point; maximum likelihood estimation method; Arithmetic; Calibration; Cameras; Geometrical optics; Laboratories; Logistics; Manufacturing automation; Nonlinear distortion; Optimization methods; Reverse engineering; Camera calibration; Planar pattern; Reverse engineering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Automation and Logistics, 2007 IEEE International Conference on
  • Conference_Location
    Jinan
  • Print_ISBN
    978-1-4244-1531-1
  • Type

    conf

  • DOI
    10.1109/ICAL.2007.4339084
  • Filename
    4339084