Title :
Sampling based RLC bridge
Author :
Overney, F. ; Jeanneret, B.
Author_Institution :
Fed. Office of Metrol. METAS, Bern-Wabern, Switzerland
Abstract :
This paper describes a measuring set up based on a synchronous sampling system which allows the calibration of any kind of impedance (resistance, inductance or capacitance) in terms of a reference resistance standard. The impedance range covered starts below 1 Ω and reaches 100 kΩ for frequencies ranging between 50 Hz and 20 kHz.
Keywords :
bridge circuits; capacitance; electric impedance; inductance; calibration; capacitance; impedance range; inductance; reference resistance standard; sampling based RLC bridge; synchronous sampling system; Bridge circuits; Calibration; Capacitance; Coaxial components; Electromagnetic measurements; Frequency; Impedance; Sampling methods; Standards development; Voltage;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
DOI :
10.1109/CPEM.2010.5544367