DocumentCode
3481605
Title
Fine output voltage control for inverter system having nonlinear load and time-delay
Author
Shibata, Junji ; Ohishi, Kiyoshi ; Ando, Itaru ; Ogawa, Mina
Author_Institution
Nagaoka Univ. of Technol., Nagaoka, Japan
fYear
2010
fDate
21-24 June 2010
Firstpage
1541
Lastpage
1546
Abstract
This paper proposes a new output voltage control for inverter system which contains time-delay and nonlinear load. In the next generation X-ray CT system with the contactless power transfer method, the feedback signal often contains some long delay time by AD/DA conversion and error detection/correction time. When the PID controller of inverter system has the harmful influence on the time-delay, it often has an overshoot and an oscillated response. In order to overcome this problem, this paper proposes the compensation method based on Smith predictor for inverter system having the time-delay and the nonlinear load which is the diode bridge rectifier. The proposed compensation method consists of Smith predictor with the equivalent analog circuit. The experimental results confirm the validity of the proposed system.
Keywords
bridge circuits; delays; equivalent circuits; error detection; feedback; invertors; nonlinear control systems; rectifying circuits; three-term control; voltage control; AD-DA conversion; PID controller; Smith predictor; X-ray CT system; contactless power transfer method; equivalent analog circuit; error detection-correction time; fine output voltage control; inverter system; nonlinear load; time-delay; Control systems; Delay effects; Diodes; Error correction; Feedback; Inverters; Three-term control; Voltage control; X-ray detection; X-ray detectors; Analog computer; Nonlinear load; Smith predictor; Time delay;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Conference (IPEC), 2010 International
Conference_Location
Sapporo
Print_ISBN
978-1-4244-5394-8
Type
conf
DOI
10.1109/IPEC.2010.5544535
Filename
5544535