DocumentCode :
3482051
Title :
Minimizing voltage lead corrections for a pulse-driven josephson voltage standard
Author :
Van den Brom, Helko E. ; Houtzager, Ernest
Author_Institution :
VSL Dutch Metrol. Inst., Delft, Netherlands
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
6
Lastpage :
7
Abstract :
This paper describes possible strategies towards minimizing or compensating the influence of the voltage leads when using a pulse driven AC Josephson voltage standard as a calculable reference source in practice.
Keywords :
measurement standards; pulse driven AC Josephson voltage standard; voltage lead compensation; voltage lead correction; Analog-digital conversion; Calibration; Frequency measurement; Impedance; Measurement standards; NIST; Performance evaluation; Pulse measurements; Standards development; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5544558
Filename :
5544558
Link To Document :
بازگشت