Abstract :
Induction motors driving the agitators in pulp tanks are affected by the leakage of pulp that coats their inter-fin channels, blocks the air inlets of the fan cover, or partially floods them. This paper presents a complete thermal evaluation of TEFC induction motors during these abnormal conditions. A totally enclosed fan cooled (TEFC) induction motor fitted with 12 thermocouples was tested in the different situations of interest, including pulp spilled over the frame, in the air intake, and partially flooding it. Winding, frame, and bearing temperatures were measured. These results are used to determine the required oversizing of an agitator motor in order to assure that the motor will not fail even if the inter-fin channels become obstructed with spilled pulp.
Keywords :
induction motors; machine bearings; machine testing; machine windings; paper industry; temperature measurement; TEFC induction motors; agitator motor; air inlets; bearing temperatures; fan cover; frame temperatures; inter-fin channels; pulp tank; rating motor; required motor oversizing; spilled pulp coating; spilled pulp flooding; thermal derating; thermal evaluation; thermocouples; totally enclosed fan cooled induction motor; winding temperatures; Coatings; Cooling; Electrical resistance measurement; Floods; IEEE members; Induction motors; Paper mills; Temperature measurement; Testing; Thermal loading;
Conference_Titel :
Pulp and Paper Industry Technical Conference, 2004. Conference Record of the 2004 Annual
Print_ISBN :
0-7803-8282-X
DOI :
10.1109/PAPCON.2004.1338356