Abstract :
Repetitive POS technology recently developed in the Kurchatov Institute may be applicable for various technology uses. Together with existing 2-3 MV 10-50 kW X-ray systems, a new facility operating in electron beam mode was recently developed for radiation sterilization applications. This compact system possesses 0.5-1 kJ/shot in electron beam of 0.5-0.8 MeV depending on the initial Marx charging voltage and may repetitively perform at 1 Hz frequency. Electron beam creates 1-10 kGy/shot in a surface layers of irradiated substances with dose rate at 5 GGy/s
Keywords :
biomedical equipment; electron beam applications; plasma switches; 0.5 to 0.8 MeV; 0.5 to 1 kJ; 1 Hz; 1 to 10 kGy; POS technology; air injected high power repetitive electron beam; dose rate; electron beam mode; initial Marx charging voltage; plasma opening switches; radiation sterilization applications; radiation treatment; Dielectrics and electrical insulation; Diodes; Electron beams; Frequency; Physics; Pulse compression methods; Pulse generation; Switches; Voltage; Water heating;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High-Power Particle Beams, 1998. BEAMS '98. Proceedings of the 12th International Conference on
Conference_Location :
Haifa
Print_ISBN :
0-7803-4287-9
Type :
conf
DOI :
10.1109/BEAMS.1998.817017
Filename :
817017
Link To Document :
بازگشت