Abstract
A calibration system for noise sources is implemented in the frequency range of 18 GHz to 26.5 GHz. For the Y-factor method, a diode noise source and one with an RF attenuator are used as standard noise sources. Measured results and evaluated uncertainty are presented.
Keywords
attenuators; calibration; measurement uncertainty; noise measurement; temperature measurement; RF attenuator; Y-factor method; calibration system; diode noise source; measurement uncertainty; noise temperature measurement; Attenuators; Electromagnetic measurements; Radio frequency; Temperature;