DocumentCode :
3486348
Title :
Reconstruction of bandlimited signal using samples obtained from integration digital voltmeters
Author :
Gubler, G.B.
Author_Institution :
D.I. Mendeleyev Inst. for Metrol., St. Petersburg, Russia
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
257
Lastpage :
258
Abstract :
The paper considers a way for extending the bandwidth of integration-type digital voltmeters (DVM) that measure RMS values and harmonic ratios of signals. The method is applicable to measurements within frequency range commonly used for determining power quality parameters. In the course of experimental study the DVM had demonstrated non-uniformity of its amplitude-frequency response less than ±20 μV/V within the 50 to 3300 Hz band.
Keywords :
digital voltmeters; signal reconstruction; signal sampling; DVM; RMS values measurement; amplitude-frequency response; bandlimited signal reconstruction; frequency 50 Hz to 3300 Hz; integration digital voltmeters; power quality parameters; signal sampling; signals harmonic ratios; Bandwidth; Circuits; Electromagnetic measurements; Frequency measurement; Frequency response; Hydrogen; Metrology; Noise measurement; Sampling methods; Voltmeters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location :
Daejeon
Print_ISBN :
978-1-4244-6795-2
Type :
conf
DOI :
10.1109/CPEM.2010.5544790
Filename :
5544790
Link To Document :
بازگشت