• DocumentCode
    3486714
  • Title

    A ultra-low power channel selection filter for low-IF FSK biomedical receivers

  • Author

    Horng-Yuan Shih ; Wei-Hsien Chen ; Kai-Chenug Juang ; Chun-Fan Chen ; Sheng-Kai Lin

  • Author_Institution
    Dept. of Electr. Eng., Tamkang Univ., Taipei, Taiwan
  • fYear
    2012
  • fDate
    4-7 Nov. 2012
  • Firstpage
    595
  • Lastpage
    597
  • Abstract
    Ultra-low power (ULP) receivers can be applied in wearable and implantable biomedical sensors. In this paper, a ULP band-pass filter designed as a channel selection filter for low-IF FSK biomedical receivers is implemented in 1.8 V 0.18 μm CMOS process. Under power consumption of 200 μW, the measured central frequency and bandwidth is 1.5 MHz and 330 kHz, respectively. As applied in a low-IF FSK biomedical receiver, data rate of 330 kb/s can be achieved.
  • Keywords
    CMOS integrated circuits; biomedical communication; biomedical electronics; prosthetics; radio receivers; radiofrequency filters; sensors; CMOS process; bandwidth 330 kHz; bit rate 330 kbit/s; frequency 1.5 MHz; implantable biomedical sensor; low-IF FSK biomedical receivers; power 200 muW; size 0.18 mum; ultralow power channel selection filter; ultralow power receiver; voltage 1.8 V; wearable biomedical sensor; FSK; biomedical; filter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Signal Processing and Communications Systems (ISPACS), 2012 International Symposium on
  • Conference_Location
    New Taipei
  • Print_ISBN
    978-1-4673-5083-9
  • Electronic_ISBN
    978-1-4673-5081-5
  • Type

    conf

  • DOI
    10.1109/ISPACS.2012.6473559
  • Filename
    6473559