DocumentCode
3487606
Title
0.18um CMOS receiver front-end for non-invasive cardiopulmonary monitoring
Author
Park, Jae-Hyung ; Jang, Byung-Jun ; Yook, Jong-Gwan
Author_Institution
Dept. of Electr. & Electron. Eng., Yonsei Univ., Seoul
fYear
2008
fDate
16-20 Dec. 2008
Firstpage
1
Lastpage
4
Abstract
In this paper, the results of simulation a receiver front-end for CW Doppler radar remote vital sign sensing is designed and simulated integrated on a chip by 0.18 um CMOS technology. This receiver has low power consumption (10 mW with 1.8 V) and low flicker noise performance. Whole CW Doppler radar system for cardiopulmonary monitoring will be implemented on PCB and experimented.
Keywords
CMOS integrated circuits; biomedical telemetry; patient monitoring; printed circuits; radar receivers; remote sensing by radar; CMOS receiver front-end; Doppler radar remote vital sign sensing; PCB; low flicker noise; low power consumption; noninvasive cardiopulmonary monitoring; size 0.18 mum; 1f noise; CMOS technology; Cardiology; Doppler radar; Monitoring; Noise figure; Noise reduction; Radio frequency; Voltage; Voltage-controlled oscillators;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 2008. APMC 2008. Asia-Pacific
Conference_Location
Macau
Print_ISBN
978-1-4244-2641-6
Electronic_ISBN
978-1-4244-2642-3
Type
conf
DOI
10.1109/APMC.2008.4958346
Filename
4958346
Link To Document