DocumentCode :
3487701
Title :
How to increase informativity of the TSDC method
Author :
Fedosov, S.N. ; Sergeeva, A.E. ; Revenyuk, T.A.
Author_Institution :
Dept. of Phys., ONAFT, Odessa, Ukraine
fYear :
2005
fDate :
11-14 Sept. 2005
Firstpage :
273
Lastpage :
275
Abstract :
Two modifications of the thermally stimulated depolarization current (TSDC) method are proposed to improve resolution and sensitivity of the method by connecting either a real capacitor or an additional resistor in series with the sample. It is shown experimentally that the high sensitivity in the TSDC method with the air gap can be obtained if the gap is substituted by the capacitor, while all advantages of the method remain in force. It was found that one could obtain in one experiment the data on the thermally stimulated conductivity (TSC) along with the TSD current, if the additional resistor is periodically switched on and off.
Keywords :
capacitors; dielectric relaxation; electrets; resistors; thermally stimulated currents; TSDC method; capacitor; electrified dielectrics; electrified electrets; relaxation processes; resistor; thermally stimulated conductivity; thermally stimulated depolarization current method; Capacitors; Current measurement; Dielectric constant; Electrets; Electrodes; Joining processes; Physics; Resistors; Thermal conductivity; Thermal resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrets, 2005. ISE-12. 2005 12th International Symposium on
Print_ISBN :
0-7803-9116-0
Type :
conf
DOI :
10.1109/ISE.2005.1612374
Filename :
1612374