DocumentCode
3489747
Title
Influence of transverse magnetic fields on prebreakdown current in non-uniform field gaps in vacuum
Author
Kolaczkowski, Z. ; Rybski, A. ; Grzybowski, S. ; Kuffel, E.
Author_Institution
Tech. Univ. of Poznan, Poland
fYear
1988
fDate
16-20 Oct 1988
Firstpage
60
Lastpage
65
Abstract
The authors report results of an experimental study into the relationship between the prebreakdown current in nonuniform field gaps in vacuum under DC voltage and the transverse magnetic field. The gaps included point-point and point-plane arrangements and spacing from 1.0 to 5.0 mm. The critical magnetic field strengths causing the interruption of current flow in these gaps were calculated. It is shown that prebreakdown current in technical vacuum contains a nonemission component. It is also shown that the transverse magnetic field with density in the range B =0.02 T up to B =0.9 T always causes a reduction in prebreakdown current in vacuum for electrode arrangements investigated
Keywords
electric breakdown; magnetic field effects; 1.0 to 5.0 mm; DC voltage; electrode arrangements; nonuniform field gaps; point-plane; point-point; prebreakdown current; transverse magnetic fields; vacuum; Breakdown voltage; Current measurement; Electric breakdown; Electrodes; Magnetic field measurement; Magnetic fields; Needles; Testing; Vacuum breakdown; Vacuum technology;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1988. Annual Report., Conference on
Conference_Location
Ottawa, Ont.
Type
conf
DOI
10.1109/CEIDP.1988.26309
Filename
26309