DocumentCode
3491117
Title
Automatic broad-range transformer bridge for measurement of capacitance and dielectric loss tangent
Author
Lameko, A.L. ; Surdu, M.N. ; Semenycheva, L.N. ; Abrosimov, E.A. ; Mamonov, A.A.
Author_Institution
GP, Ukrmetrteststandart, Kiev, Ukraine
fYear
2012
fDate
2-4 Oct. 2012
Firstpage
32
Lastpage
39
Abstract
The precise transformer bridge have been designed that enables to transfer values of capacitance unit and dielectric loss tangent unit from basic reference standard to secondary and working reference standards of these units.
Keywords
bridge circuits; capacitance measurement; dielectric loss measurement; transformers; automatic broad-range transformer bridge; basic reference standard; capacitance measurement; dielectric loss tangent measurement; working reference standards; Bridge circuits; Capacitance; Capacitance measurement; Dielectric loss measurement; Dielectrics; Standards; Zinc;
fLanguage
English
Publisher
ieee
Conference_Titel
Actual Problems of Electronics Instrument Engineering (APEIE), 2012 11th International Conference on
Conference_Location
Novosibirsk
Print_ISBN
978-1-4673-2842-5
Type
conf
DOI
10.1109/APEIE.2012.6628948
Filename
6628948
Link To Document