  • Abstract
    Highly dynamic stator-flux-oriented controls need an exact model-based observer of the induction machine to predict the non-measurable fluxes and to calculate the speed in sensorless operation. Inverter voltage errors cause inaccuracy and instability in the observer. Therefore an offline-measurement procedure without any additional measurement devices is presented, to identify the error voltages. An online correction is introduced and verified by measurement results.
  • Keywords
    asynchronous machines; error correction; invertors; observers; sensorless machine control; stability; stators; voltage control; inaccuracy; induction machine control; instability; inverter voltage error; nonmeasurable flux; observer; offline measurement procedure; online correction; sensorless operation; stator flux oriented control; Automatic voltage control; Error correction; Induction machines; Inverters; Motion control; Predictive models; Sampling methods; Sensorless control; Stators; Voltage control; drive control; inverter voltage errors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Electrical Drives Automation and Motion (SPEEDAM), 2010 International Symposium on
  • Conference_Location
    Pisa
  • Print_ISBN
    978-1-4244-4986-6
  • Electronic_ISBN
    978-1-4244-7919-1
  • Type

    conf

  • DOI
    10.1109/SPEEDAM.2010.5545127
  • Filename
    5545127