• DocumentCode
    3491801
  • Title

    Analysis and performance of a three-phase AC generator with inset permanent-magnet rotor

  • Author

    Chan, T.F. ; Yan, Lie-Tong ; Lai, L.L.

  • Author_Institution
    Dept. of Electr. Eng., Hong Kong Polytech., Kowloon, China
  • Volume
    2
  • fYear
    2000
  • fDate
    30 Oct.-1 Nov. 2000
  • Firstpage
    436
  • Abstract
    This paper presents the analysis and performance of a three-phase AC generator with an inset permanent magnet rotor. It is shown that the generator exhibits inverse saliency, with a consequent improvement in voltage regulation. The finite element method is used for computing the magnetic field distribution, from which the synchronous reactances, and hence the generator performance, may be determined. The theoretical analysis is verified by experiments performed on a 2.5 kVA prototype generator.
  • Keywords
    AC generators; electric reactance; finite element analysis; machine control; machine theory; magnetic fields; permanent magnet generators; rotors; voltage control; 2.5 kVA; finite element method; inset permanent-magnet rotor; inverse saliency; magnetic field distribution; performance; synchronous reactances; three-phase AC generator; voltage regulation improvement;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Advances in Power System Control, Operation and Management, 2000. APSCOM-00. 2000 International Conference on
  • Print_ISBN
    0-85296-791-8
  • Type

    conf

  • DOI
    10.1049/cp:20000438
  • Filename
    950387