DocumentCode
3491801
Title
Analysis and performance of a three-phase AC generator with inset permanent-magnet rotor
Author
Chan, T.F. ; Yan, Lie-Tong ; Lai, L.L.
Author_Institution
Dept. of Electr. Eng., Hong Kong Polytech., Kowloon, China
Volume
2
fYear
2000
fDate
30 Oct.-1 Nov. 2000
Firstpage
436
Abstract
This paper presents the analysis and performance of a three-phase AC generator with an inset permanent magnet rotor. It is shown that the generator exhibits inverse saliency, with a consequent improvement in voltage regulation. The finite element method is used for computing the magnetic field distribution, from which the synchronous reactances, and hence the generator performance, may be determined. The theoretical analysis is verified by experiments performed on a 2.5 kVA prototype generator.
Keywords
AC generators; electric reactance; finite element analysis; machine control; machine theory; magnetic fields; permanent magnet generators; rotors; voltage control; 2.5 kVA; finite element method; inset permanent-magnet rotor; inverse saliency; magnetic field distribution; performance; synchronous reactances; three-phase AC generator; voltage regulation improvement;
fLanguage
English
Publisher
iet
Conference_Titel
Advances in Power System Control, Operation and Management, 2000. APSCOM-00. 2000 International Conference on
Print_ISBN
0-85296-791-8
Type
conf
DOI
10.1049/cp:20000438
Filename
950387