DocumentCode :
3492673
Title :
Modelling and parameter identification of an alternator of the LG3 power station taking account of magnetic saturation
Author :
Tahan, Souheil-Antoine ; Kamwa, Innocent ; Paiement, Bernard ; Simo, Jean-Bertos
Author_Institution :
Dept. de Genie Electr., Laval Univ., Que., Canada
Volume :
2
fYear :
1995
fDate :
5-8 Sep 1995
Firstpage :
1096
Abstract :
A 202 MW alternator at the Quebec LG3 station is modelled by means of a structure of generalised equivalent circuits. The type of test used is the response to a disturbance of the order of 15% injected into the inductor in normal operation. To model the magnetic saturation in the direct axis, actual open-circuit test measurements are utilised. The saturation factor method is used in the nonlinear model of the machine
Keywords :
alternators; equivalent circuits; machine theory; parameter estimation; power stations; 202 MW; LG3 power station; Quebec; alternator; disturbance injection; generalised equivalent circuits; inductor; magnetic saturation; modelling; nonlinear model; open-circuit test measurements; parameter identification; saturation factor method; Content addressable storage; Magnetic circuits; Magnetic flux; Saturation magnetization; Stators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 1995. Canadian Conference on
Conference_Location :
Montreal, Que.
ISSN :
0840-7789
Print_ISBN :
0-7803-2766-7
Type :
conf
DOI :
10.1109/CCECE.1995.526621
Filename :
526621
Link To Document :
بازگشت