DocumentCode :
3492838
Title :
Coaxial multiplexer for high accuracy capacitance measurements
Author :
Overney, F. ; Corminboeuf, D. ; Moll, E.
Author_Institution :
Fed. Office of Metrol. METAS, Bern-Wabern, Switzerland
fYear :
2010
fDate :
13-18 June 2010
Firstpage :
420
Lastpage :
421
Abstract :
To automate the calibration of capacitance standards, an eight channel coaxial multiplexer has been developed to be used with a widely used commercial capacitance bridge. The use of the multiplexer doesn´t worsen the intrinsic uncertainty of the bridge for capacitors of 10 pF and above. For a 1 pF standard, the use of the multiplexer affect the uncertainty only at frequencies higher than 2 kHz.
Keywords :
calibration; capacitance measurement; multiplexing equipment; capacitance 1 pF; capacitance standards calibration; coaxial multiplexer; commercial capacitance bridge; high accuracy capacitance measurements; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Coaxial components; Connectors; Frequency; Measurement standards; Multiplexing; Relays;